Site Information

 Loading... Please wait...

KinExA Autosampler

KinExA Autosampler

The Autosampler provides KinExA 3200 users increased productivity by enabling unattended operation through multiple experiments. It is a versatile and efficient addition to assist in the determination of binding characteristics. Features include:

  • Four particle reservoirs - accommodates up to four distinct solid phase preparations and, in conjunction with up to 270 samples, supports robust characterizations.
  • Autonomous measurements - enables the measurement of completely different systems, multiple curves, or a combination of both.
  • KinExA Pro software - easily queues experiments and may be set to begin measurements at specific incubation times.
  • Enhanced instrument fluidics - decrease the need for excess sample volume compared to the standard 3200 instrument.

Optional Accessories

  •  
    Microtiter Dual Plate Rack (414106) - These racks take the place of [2] sample racks on the Autosampler. They are designed to support the use of any [2] of the following: 96 sample microtiter plates, custom 48 Sample Microcentrifuge Racks (414148), or 24 sample microtiter plates.
  •  
    48 Sample Microcentrifuge Rack (414148) - This custom rack supports the use of Low Dead Volume Microcentrifuge Tubes (A02312) and standard microcentrifuge tubes to minimize dead volume.
  •  
    Low Dead Volume Microcentrifuge Tubes (A02312) - These tubes can be used in conjunction with the 48 Sample Microcentrifuge Rack (414148) to reduce the amount of dead volume needed for a typical experiment. The dead volume can be reduced to as low as 10 μL. For more information see Tech Note 206 Minimum Sample Volumes.
  •  
    EZ-Perce Sealing Films (A04030) - These films can be used to minimize evaporation of small volume samples in microtiter plates or microcentrifuge tubes during long incubation times.
  •  
    X-Pierce Piercaeable Sealing Films (A04035) - These films are designed with a cross cut to allow entry of the sipper tube during sensitive experiments that require the samples to remain covered.
‚Äč

Specifications

Size
(H x W x D cm)
52.2 x 28.1 x 56.5 
 
 
Weight
21 kg (46 lbs) 
 
Sample Racks 
Part
414042
414045
414048
Any combination of 3 racks
Description
90 positions for 5 mL tubes
60 positions for 15 mL tubes
21 positions for 50 mL tubes
 
Standards Rack
6 spaces for 50 mL tubes 
 
 
 

Requirements

Instruments
 KinExA 3200
 
Power
 
 
 
100-240 V 
50-60 Hz
1.8 A (max)
65 W (avg)
 
 

Optional Accessories

  •  
    Microtiter Dual Plate Rack (414106) - These racks take the place of [2] sample racks on the Autosampler. They are designed to support the use of any [2] of the following: 96 sample microtiter plates, custom 48 Sample Microcentrifuge Racks (414148), or 24 sample microtiter plates.
  •  
    48 Sample Microcentrifuge Rack (414148) - This custom rack supports the use of Low Dead Volume Microcentrifuge Tubes (A02312) and standard microcentrifuge tubes to minimize dead volume.
  •  
    Low Dead Volume Microcentrifuge Tubes (A02312) - These tubes can be used in conjunction with the 48 Sample Microcentrifuge Rack (414148) to reduce the amount of dead volume needed for a typical experiment. The dead volume can be reduced to as low as 10 μL. For more information see Tech Note 206 Minimum Sample Volumes.
  •  
    EZ-Perce Sealing Films (A04030) - These films can be used to minimize evaporation of small volume samples in microtiter plates or microcentrifuge tubes during long incubation times.
  •  
    X-Pierce Piercaeable Sealing Films (A04035) - These films are designed with a cross cut to allow entry of the sipper tube during sensitive experiments that require the samples to remain covered.